A4 Quattro Sedan L4-2.0L Turbo (CAEB) (2009)
Auxiliary Power Outlet: Service and Repair
12V Socket 2
12V Socket 2
Special tools, testers and auxiliary items required
‹› Release tool (T40148)
Removing
-
The release tabs - 2 - on the release tool ( T40148) must engage in the openings in the 12V socket - 3 - - arrow - and the threaded pin - 1 - must
slide down as far as the stop.
-
Open cover - 2 - on the 12 V socket and hold it in this position.
-
Slide release tool (T40148) as far as stop into the 12V socket - 3 -.