audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor HO2S, Checking|Page 3772 > < Heated Oxygen Sensor HO2S, Checking|Page 3770
Page 2
background image

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check

Start diagnosis

-

Connect scan tool.

-

Start the engine and let it run at idle.

-

Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

-

Select "Test-ID 02: Oxygen sensor monitoring behind catalytic converter".

-

Select following Test-IDs.

-

Check the specified values at idle.

If the specified values are obtained:

-

End diagnosis and switch ignition off.

If the specified values are not obtained:

-

Remove the right vehicle floor cover - arrows -.

Checking primary voltage

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  arrow -.

Heated Oxygen Sensor HO2S, Checking|Page 3772 > < Heated Oxygen Sensor HO2S, Checking|Page 3770