background image

-

Replace the Intake Manifold Runner Control (IMRC) Valve (N316).

If the specified value was obtained:

Checking voltage

Switch the ignition on.

-

Using a multimeter, check the Intake Manifold Runner Control (IMRC) Valve (N316) electrical harness connector terminal 1 to ground (GND) for
voltage.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring from the Intake Manifold Runner Control (IMRC) Valve (N316) electrical harness connector terminal 1 to fuse SB7 on fuse
panel B.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Engine Control Module (ECM) (J623).

-

Using a multimeter, check the Intake Manifold Runner Control (IMRC) Valve (N316) electrical harness connector terminal 2 to the Engine
Control Module (ECM) (J623) electrical harness connector terminal 36 for resistance.

Specified value: 1.5 ohms Max.

If the specification was not obtained:

Variable Induction Control Valve|Testing and Inspection|Page 4426 > < Variable Induction Control Valve|Testing and Inspection