Using a diode test lamp, check the Ignition Coil electrical harness connector terminals 2 to 3 for voltage.
-
Operate the starter.
The LED should flicker.
-
Switch the ignition off.
If the LED flickers and the voltage was OK:
-
Replace the faulty Ignition Coils with Power Output Stage (N70, N127, N291, N292). Refer to appropriate service manual.
If the LED does not flicker:
Checking wiring
If the manufacturers test box is being used, perform the following step.
-
Install the test box.
If the manufacturers test box is not being used, perform the following step.
-
Remove the Motronic Engine Control Module (ECM) ( J623).
-
Using a multimeter, Check the Ignition Coil electrical harness connector to the Motronic Engine Control Module (ECM) (J623) electrical harness
connector T60 for an open circuit.