audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor HO2S, Checking|Page 3347 > < Heated Oxygen Sensor HO2S, Checking|Page 3345
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor O2S 1 Heater Before Catalytic Converter, Checking

Oxygen Sensor O2S 1 Heater Before Catalytic Converter, Checking

Observe all safety precautions: => [ Safety Precautions ] See: Computers and Control Systems/Service Precautions/Safety Precautions

View clean working conditions: => [ Clean Working Conditions ] See: Computers and Control Systems/Service Precautions/Clean Working
Conditions

Use only gold-plated terminals when servicing any component with gold-plated electrical harness connector terminals.

For wiring diagrams, component locations, and connector views, Refer to the applicable wiring diagram.

‹› Oxygen Sensor (O2S) 1 Before Catalytic Converter Heater ( Z29) is part of Oxygen Sensor (O2S) Before Three Way Catalytic Converter (G130)

and cannot be replaced separately. 

Special tools, testers and auxiliary items required

‹› multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SB21) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check.

Start diagnosis

-

Remove right cover from vehicle underbody. 

Checking internal resistance

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  1 -.

Heated Oxygen Sensor HO2S, Checking|Page 3347 > < Heated Oxygen Sensor HO2S, Checking|Page 3345