A4 Quattro Sedan V6-3.0L (AVK) (2002)
Indicated on display (function selection):
-
Press 8.
-
Remove the diagnostic cable from the diagnostic connection.
Or:
Indicated on display (function selection):
If after the test the system is not OK, read out the fault memory and rectify the fault (ignition OFF).
-
Afterward perform the short trip again.
Performing final control diagnosis
-
Connect the scan tool and select the engine electronics function.
-
Press -key.
Indicated on display (function selection):
-
Press keys O and 3 for "Final control diagnosis" and confirm the entry with the Q key.
-
Press the Key until the following text appears:
Indicated on display (function selection):
-
Confirm the entry with the Q key.
The electric vacuum pump should now run for approximately 10 sec.
-
Remove the diagnostic cable from the diagnostic connection.