Check the following wire connection for open circuit and short circuit to Ground (GND) or to plus (B+):

Electrical connector terminal

Test box VAG1598/22 socket

2

16

-

Repair wiring or short circuit as necessary.

If you did not find any malfunction, however the Leak Detection Pump (LDP) did not function during the output Diagnostic Test Mode (DTM):

-

Replace Leak Detection Pump (LDP) -V144.

If the LED does not blink, although wiring is OK:

-

Replace Engine Control Module (ECM):

-

Generate readiness code: