Active Check Module: Service and Repair

Adaptation (Scan Tool Function 10)

Individual functions are called up by entering the appropriate adaptation channel numbers (listed in the adaptation table).

NOTE:

-

Using measuring value blocks 10, 11, 12 and 15, the values that need to be transferred to the new instrument cluster can be read out before
replacement.

-

Adaptation channels 42, 43, and 44 (See measuring value blocks 013 and 014) must be adapted according to the oil quality (measuring value block
15).

-

Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system..

-

Measuring value blocks 125 and 126 indicate the components that are part of the powertrain data-BUS.

-

Measuring value block 130 indicates the components that are part of the comfort system data-BUS.

-

Measuring value block 140 indicates the components that are part of the information data-BUS.

Adaptation table :
Adaptation channel

Adaptation function

02

Resetting SRI after service 

03

Adaptation of fuel gauge 

04

Language version of driver information display

09

Odometer

18

Adaptation of auxiliary heater

30

Adaptation of fuel gauge sender resistance range 

35

Adaptation of engine speed threshold 

40

Adaptation for distance driven since service 

41

Adaptation for time since service 

42

Adaptation for minimum mileage performance 

43

Adaptation for maximum mileage performance 

44

Adaptation for maximum time interval 

45

Adaptation for oil quality 

46

Adaptation for total consumption quantity (only gasoline engines)

60

Adaptation powertrain data-BUS 

61

Adaptation comfort system data-BUS 

62

Adaptation information data-BUS 

Initiating "Adaptation" function 10

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -1- and -0-. This selects "Adaptation", function 10.

-

Press -Q- button to confirm input.

Indicated on display

Rapid data transfer

Q

10-Adaptation

-

Press -Q- button to confirm input.

Indicated on display:

Adaptation
Input channel number XX

-

Enter desired adaptation channel (adaptation table).

-

Press -Q- button to confirm input.

NOTE:  After changing an adaptation value or ending an adaptation channel, "Adaptation" function 10 must be performed again before selecting another
adaptation channel.