A4 Quattro Wagon L4-1.8L Turbo (ATW) (2000)
Maintenance Required Lamp/Indicator: Service and Repair
Channel 44 (Max Time Interval Until Service)
Maximum Time Interval
This function is used to set a fixed maximum time in days in the instrument cluster for the SRI.
Initiate Adaption Function. See: Adaptation Function Initiation
Indicated on display
-
Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
-
Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
-
Press buttons 4- and -4-.
-
Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 ->
max-value Insp. in 1 days <- 1 3 ->
The display indicates the maximum time interval in days to the next service (for example, 365 represents 365 days).
Note:
-
The adaptation value entered for the relevant engine variant must match the value in the table. Please refer to Adaptation values. See: Table
For Channels and Adaption Values
-
Input of current specified value is only possible in units of one day, therefore indication in display also changes in one day units.
-
Values can only be input directly using the scan tool keypad.
-
If an incorrect value is input, the 'Adaptation" function is terminated and must be re-initiated.
-
Press -> button.
Indicated on display:
Channel 44 Adaptation 365
Input adaptation value XXXXX
-
Input specified value using keypad, filling initial positions with "0".
Input value: for example 365 days.
Keypad input: 00365
Indicated on display:
Channel 44 Adaptation 365 Q
Input adaptation value 00365
-
Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 Q
max-value Insp. in 1 days <- 1 3 ->
-
Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 Q
Store changed value?
-
Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 ->
Changed value stored