audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Injection Pump Relay|Locations|Page 7068 > < Air Injection Pump Relay|Locations|Page 7066
Page 2
background image

-

The Secondary Air Injection (AIR) pump relay (in 3-socket relay carrier in the E-box, at left in plenum chamber, position 2) must trigger and
the Secondary Air Injection (AIR) pump motor 4101- must run in intervals

A - If relay does not trigger:
^

Check voltage supply of Secondary Air

^

Injection (AIR) relay.

^

Checking activation of Secondary Air Injection (AIR) relay.

B - If relay triggers, but Secondary Air Injection (AIR) pump does not run:
^

Check voltage supply for Secondary Air Injection (AIR) pump.

Checking voltage supply of Secondary Air Injection (AIR) pump relay 
^

Remove Secondary Air Injection (AIR) pump relay.

^

Connect multimeter for voltage measurement as follows.

-

Specified value: approximately battery voltage

If specified value is not obtained:
^

Perform the following tests marked with dots:

Air Injection Pump Relay|Locations|Page 7068 > < Air Injection Pump Relay|Locations|Page 7066