A4 Quattro Wagon L4-1.8L Turbo (AWM) (2001)
Vacuum Solenoid Valve HVAC: Service and Repair
Fresh Air/Recirculating Flap Two- Way Valve -N63-, Removing and Installing
Remove glovebox
-
Remove bolt -A-.
-
Separate electrical connection.
-
Install in reverse order of removal.
NOTE:
-
Connect vacuum hoses correctly (hose - B- to vacuum reservoir, hose -C- to vacuum unit).
-
Vacuum hose layout.
-
Testing -N63-, output Diagnostic Test Mode (DTM).
-
Electrical test.