background image

NOTE:  Display field "4" indicates operating status of air conditioner (fresh-air or recirculated-air mode), whereas display zone "3" shows status
of Air Quality Sensor G238 signal. Remarks on possible displays and

Specified value in display zone "4"
-

"00" (no request for "recirculated-air mode" , air conditioner in fresh-air mode)

Or
-

"60" ("partial recirculated-air mode", fresh-air and recirculated-air flap open)

-

Position spray attachment - A - of test gas canister over air inlet of Air Quality Sensor G238 - B - (with version "1" of Air Quality Sensor G238 ).

-

Position spray attachment - A - of test gas canister over air inlet of Air Quality Sensor G238 - B - (with version "2" of Air Quality Sensor G238 ).

-

Press spray knob - C - of test gas canister for approx. 1 second.

NOTE:
-

There are different Air Quality Sensor G238 housings. Version "1" was installed at the start of production. This sensor is gradually being
replaced by version "2", however the mode of operation is identical.

-

The test gas canister is filled with pure oxygen with a specific nitrogen oxide component.

-

The Air Quality Sensor G238 also reacts when exposed to cigarette smoke or cigarette lighter gas (gas is heavier than air, the Air Quality
Sensor G238 must therefore be removed and turned round).

-

Read off display in zone "4".

Specified value:
-

"10" ("Automatic air recirculation mode" requested, request met, air conditioner switches to recirculated-air mode)

-

Wait briefly approx. 1 minute, depending on amount of test gas sprayed onto Air Quality Sensor G238).

-

Read off display in zone "4".

Specified value:
-

"00" (no request for "recirculated-air mode" , air conditioner in fresh-air mode)

Or
-

"60" (Partial recirculated-air mode)

NOTE:  To stop the recirculated-air/fresh-air flaps being switched too frequently, an Air Quality Sensor G238 request for "automatic
recirculated-air mode" is applied for at least 25 s (minimum dwell time) even if the pollutant concentration in the air has decreased to such an
extent that recirculated-air mode would no longer be necessary.