Battery: Testing and Inspection
No-Load Voltage, Checking

No-load Voltage, Checking

Special tools, testers and auxiliary items required

-

Multimeter VAG 1526 B, Fluke 83 or equivalent

Test requirements

-

Always heed the following, otherwise correct measurement is not guaranteed.

NOTE:

-

If no load voltage measurement is carried out with the battery installed in vehicle, disconnect negative (-) battery terminal.

-

The battery must not be loaded by connected power consumers for at least 2 hours before making measurements.

-

The battery must not be charged for at least 2 hours before making the measurements.

CAUTION:

-

On vehicles equipped with Audi Telematics by OnStar(R), switch-off the emergency (back- up) battery for the Telematic/Telephone Control
Module prior to disconnecting vehicle battery

-

After reconnecting vehicle battery, re-code and check operation of anti-theft radio. Also check operation of clock and power windows according to
Owners Manual.

-

After reconnecting vehicle battery on vehicles equipped with Audi Telematics by OnStar(R), switch-on the emergency (back-up) battery for the
Telematic/Telephone Control Module

-

Switch off all electrical consumers.

-

Switch the ignition off and remove ignition key.

-

Slide battery cover to right - arrow 1- and lift off - arrow 2- where applicable.