audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser HVAC|Service and Repair|Page 9572 > < Compressor Pulley|Page 9568
Page 1
background image

Condenser HVAC: Service and Repair

Condenser

‹› The radiator and condenser may have small indentations on the fins even when installed correctly. It is not damage. Do not replace the radiator or

condenser because of those small indentations.

‹› Slight deformations on the side securing straps on the condenser, for example, due to an accident), can result in an unparallel flow from the

condenser and radiator; this can be resolved by pulling the straps back as long as the function/condenser sealing is not impaired. The straps on the
condenser do not need to be replaced if there are small deformations.

‹› A slight bending of the condenser (up to 4 mm) is permissible as long as there is sufficient distance (minimum 4 mm) between the condenser and

the radiator and the function/sealing of the condenser (of the refrigerant circuit) is not impaired. The condenser does not have to be replaced if
there are slight deformations.

‹› Condenser is available in different versions, depending on version of vehicle.

Removing

-

Switch off ignition.

-

Drain the refrigerant circuit. Refer to A/C system - with refrigerant R134a.

‹› Depending on the allocation of the service connection an on the refrigerant line, and on the version of the vehicle, it may be necessary to remove

the additional reinforcement on the left suspension strut dome so that the service coupling of the service station can be connected (for example, on
the Audi Q5). Refer to and Heating/Ventilation/Air Conditioning; Air Conditioning with R134a refrigerant.

-

Remove the refrigerant lines from the condenser. Refer to => [ Disconnecting and Connecting Refrigerant Lines from Condenser ] See:
Compressor HVAC/Service and Repair.

-

Remove the bolts - 1, 2, 3, 5 -. Refer to Removal and Installation.

-

Remove the cover - 4 - from the lock carrier and hang it on the radiator grille. Refer to Removal and Installation

-

Remove the bolts - arrows -.

Condenser HVAC|Service and Repair|Page 9572 > < Compressor Pulley|Page 9568