audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

A/C Unit Air Intake Housing|Page 9870 > < A/C Unit Air Intake Housing
Page 2
background image

‹› Actuated by two levers, the back pressure- and fresh air door

‹› Apply a small quantity of Grease (G 000 150) to the cam plate guides as well as to the pins at the door levers.

4

Air Flow Door Motor (V71)

‹› Removing and installing, refer to => [ Air Flow Door Motor ] See: Air Door/Air Door Actuator / Motor/Service and Repair/Removal and

Replacement/Door Motors

5

Screw

6

Control Motor Door Motor (V113)

‹› Removing and installing, refer to=> [ Air Flow Door Motor ] See: Air Door/Air Door Actuator / Motor/Service and Repair/Removal and

Replacement/Door Motors

7

Latch

‹› To lock the air intake housing to the A/C

8

Upper Part of the Air Intake Housing

‹› Do not disassemble further, it is welded around at different points with the lower part.

‹› If one of the retaining tabs has broken off or if one of the welded points no longer holds, both housing parts can be bolted together with screws,

refer to=> [ (Item 5) Screw ].

‹› Different versions (with and without a connection for glove compartment cooling), this illustration shows the version without the connection.

9

Lower Part of the Air Intake Housing

‹› Do not disassemble further.

‹› If one of the retaining tabs has broken off or if one of the welded points no longer holds, both housing parts can be bolted together with screws,

refer to=> [ (Item 5) Screw ].

10

Fresh Air Blower (V2)

‹› Removing and installing, refer to => [ Fresh Air Intake ] See: Air Register/Service and Repair/Instrument Panel Vents and Air Ducts

‹› Checking, refer to Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

‹› Beginning August 2007, as a running change, Fresh Air Blower (V2) with an additional foam jacket installed on the housing (as a noise

insulation). Refer to=> [ Fresh Air Intake ] See: Air Register/Service and Repair/Instrument Panel Vents and Air Ducts.

‹› As a running change in MY 2009, a Fresh Air Blower ( V2) with a revised housing with an optimized motor and motor mount, is being used. The

new fresh air blower (V2) does not have the foam jacket on the housing because the larger motor mount has a new insulation mat. Refer to => [
(Item 14) Insulation Mat ].

11

Fresh Air Blower Control Module (J126)

‹› Removing and installing, refer to => [ Fresh Air Blower Control Module ] See: Service and Repair/Removal and Replacement/A/C System

Control and Regulation Components

‹› Checking, Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

12

Dust And Pollen Filter

‹› Removing and installing, refer to => [ Dust and Pollen Filter ] See: Service and Repair/Removal and Replacement/A/C System Control and

Regulation Components

‹› Follow the replacement intervals. Refer to maintenance tables.

‹› Different versions with and without activated charcoal filter element. Refer to=> [ Air Quality Sensor ] See: Description and Operation/A/C

System Control