audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

All Technical Service Bulletins for Auxiliary Power Outlet:|571018|Page 7569 > < Tools and Equipment|Wiring|Page 7562
Page 1
background image

Auxiliary Power Outlet: All Technical Service Bulletins
Electrical - Accessory Electrical Outlets Are Inop.

90 All 12-volt accessory outlets are inoperative

57 10 18 

2020795/6 

March 25, 2010. 

Supersedes Technical Service Bulletin Group 57 number 10-11 dated February 12, 2010 for reasons listed below.

Affected Vehicles

Condition

^ All 12-volt accessory outlets are inoperative.

^ The cutoff stages from the Data Bus On Board Diagnostic Interface J533 are not active.

^ The sockets can be activated via the Output Diagnostic Test Mode (DTM).

Technical Background

Fault in the convenience system control module (J393) software.

Production Solution

Optimized convenience system control module (J393) software.

All Technical Service Bulletins for Auxiliary Power Outlet:|571018|Page 7569 > < Tools and Equipment|Wiring|Page 7562