A4 Quattro Wagon L4-2.0L Turbo (CAEB) (2009)
Primary Connector with Flat Terminal Connector Systems
Procedure
‹› If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing contacts => [
Secondary Lock ].
Flat connector system with one retaining tab:
-
Guide release tool (which fits terminal housing) into release channel on terminal housing.
-
Grasp contact at wire and push gently into terminal housing - arrow -.
‹› By pushing contact in direction of terminal housing, contact retaining tab is lifted off the housing shoulder and can be released using release tool.
-
At the same time, push release tool in direction of terminal housing and pull released contact out of terminal housing - arrow -.
-
Remove release tool after removing contact from housing.
Flat connector system with two retaining tabs: