audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Data Bus OBD Interface Assembly Overview|Page 3918 > < Data Bus OBD Interface Assembly Overview|Page 3916
Page 1
background image

Information Bus: Service and Repair
Data Bus OBD Interface

Data Bus OBD Interface

Special tools, testers and auxiliary items required

‹› Protective Cap For Cable Connector (VAS 6223/9) from Fiber Optic Plier Repair Set (VAS 6223)

Removing

-

If the control module was replaced, select the "Replace" function for the respective control module in "Guided Fault Finding" or " Guided
Functions".

-

Select the function or path:

-

Follow further instructions on display of (VAS 5051B).

-

Switch off ignition and remove ignition key.

-

Remove glove compartment. 

-

Remove bolt - 2 -.

-

Pivot data bus on board diagnostic interface ( J533) - 3 - out of the bracket - arrow -. 

-

Disconnect electrical connector - 4 -.

-

Disconnect fiber optic cable connector - 1 -.

-

Seal open wiring harness fiber optic connector - 2 - with Wiring Harness Connector Protective Cap (VAS 6223/9) -  item 1 -.