audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Canister Purge Control Valve|Testing and Inspection|Page 4303 > < Canister Purge Control Valve|Testing and Inspection|Page 4301
Page 4
background image

-

Using a multimeter, check the electrical harness connector for voltage. 

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) ( J623).

-

Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to Motronic
Engine Control Module (ECM) (J623 ) electrical connector T60 terminal 35 for an open circuit.

Canister Purge Control Valve|Testing and Inspection|Page 4303 > < Canister Purge Control Valve|Testing and Inspection|Page 4301