A4 Quattro Wagon L4-2.0L Turbo (CAEB) (2009)
-
Using a multimeter, check the electrical harness connector for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
-
Switch the ignition off.
If the specified value was not obtained:
If the manufacturers test box is being used, perform the following step.
-
Install the test box.
If the manufacturers test box is not being used, perform the following step.
-
Remove the Motronic Engine Control Module (ECM) ( J623).
-
Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to Motronic