audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Variable Induction Position Sensor|Locations|Page 4630 > < Variable Induction Position Sensor|Locations|Page 4628
Page 3
background image

If the specified value was not obtained:

-

Check and/or repair wiring as required.

If the specified value was obtained:

Checking internal resistance

-

Using a multimeter, check the Intake Manifold Runner Position Sensor (G336) electrical terminals 2 to 3 for resistance. 

Specified value: 7-25 ohms (at approx. 20° C)

-

Using a multimeter, check the Intake Manifold Runner Position Sensor (G336) electrical terminals 1 to 3 for resistance. 

Specified value: 244 [+/- 40] ohms (at approx. 20° C)

If the specified values were not obtained:

-

Replace the Intake Manifold Runner Position Sensor (G336).

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) ( J623).

-

Using a multimeter, check the Intake Manifold Runner Position Sensor (G336) electrical harness connector terminals to the Motronic Engine
Control Module (ECM) (J623) electrical harness connector T60 terminals for an open circuit.

Specified value: 1.5 ohms Max.

If the specification was not obtained:

-

Check the wiring for a short circuit to Battery (+), or an open circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring:

-

Replace the Motronic Engine Control Module (ECM) (J623).

-

Install the engine cover with air filter. Refer to appropriate service manual.

Final procedures

After the repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] See: Computers and Control Systems/Testing and

Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09. 

Variable Induction Position Sensor|Locations|Page 4630 > < Variable Induction Position Sensor|Locations|Page 4628