audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

LED Test Light|Page 8586 > < LED Test Light|Page 8584
Page 1
background image

Canister Purge Control Valve: Testing and Inspection

Evaporative Emissions (EVAP) Canister Purge Regulator Valve, Checking

WARNING!
Whenever carrying out work on the fuel supply and/or fuel injection systems, read and carefully follow the Cautions, Warnings, and rules of
cleanliness.

Required special tools and test equipment

-

VAG1551 or VAG1552 Scan Tool (ST) with VAG1551/3 adapter cable

Test conditions

-

Engine coolant temperature at least 80 °C (176 °F)

Function check

-

Connect VAG1551 or VAG1552 scan tool and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (with engine running at
idle). Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks/Connecting VAG 1551/1552 Scan Tool" See: Computers and Control
Systems/Testing and Inspection 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block

HELP 

Input display group number XXX

-

Press buttons -0-, -7- and -0- to input display group number 70 (070), and press -Q- button to confirm input.

Indicated on display (1-4 display fields)

Read Measuring value Block 70

->

1 2 3 4

-

Press button -4- to select "Basic Setting" function 04 (diagnosis for EVAP canister purge regulator valve is initiated).

NOTE:  During this diagnosis there should not be any load placed on the engine, otherwise the diagnosis is interrupted and must be started again.

Indicated on display (1-4 = display fields)

System in Basic Setting 70

->

1 2 3 4

If the diagnosis is initiated by the ECM, the display changes from "Test OFF" to "Test ON" in display field 4.

-

Continue to run engine at idle until "EVAP OK" is indicated in display field 4.

NOTE:  If the display changes from "Test ON" to "Test OFF" during the test, accelerate with a brief burst to repeat the test.

LED Test Light|Page 8586 > < LED Test Light|Page 8584