A4 Quattro Wagon V6-3.0L (AVK) (2002)
Air Door Actuator / Motor: Service and Repair
Recirculation Flap Motor -V113-, Removing and Installing
Recirculation Flap Motor -V113-, Removing And Installing
Removing
-
Remove glove compartment.
-
Disconnect connector -A-.
-
Unscrew bolts -B-.
-
Pull connection element -C-of positioning motor out of recirculated air flap shaft -D-
Installing
NOTE: The connecting element on the positioning motor is color coded, on Recirculation Flap Motor -V113- it is blue.
Install all removed parts in reverse order, observe the following while doing so:
-
Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm of the positioning motor).
-
Check DTC memory and erase DTC memory; initiate basic setting.
-
The function of the positioning motor can be checked for example: Connect both terminals "5" and "6" in positioning motor connector to 12V
(DC), the motor moves in one direction until stop, the direction of rotation changes by reversing B+ and Ground. Use adapter cable for this.