Air Register: Service and Repair
Defroster Intermediate Piece For Front Windshield

Defroster Vent Intermediate Piece For Front Windshield, Removing And Installing

Removing

-

Remove instrument panel:

-

Loosen brake pedal mounting bracket (and clutch pedal) from central tube.

-

Loosen hex nuts -A- for central tube left side and unscrew approx. 15 mm.

-

Remove hex nuts -B- for central tube on right side.

-

Remove connecting screws between central tube and the windshield cross member (in passenger compartment).

-

Remove connecting screws between central tube and the plenum chamber (between electronic box and windshield cross member in plenum
chamber).

-

Pull central tube carefully back, until it touches the hex nuts on the left side and still rests on the threaded bolt on the right side.

-

Loosen intermediate piece -A- from central tube -B-

-

Remove intermediate piece -A-.

Installing

NOTE:

-

When installing the instrument panel, make sure that the intermediate piece for defrost fits properly on the defrost vent and that it is not pinched.

-

After installing the instrument panel, check vent direction and air distribution of flowing air coming from the defrost vent to windshield.