audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Test Chart 1|Page 4232 > < Test Chart 1|Page 4230
Page 3
background image

-

Connect the assisting hose - arrow - to the pressure gauge and hold in the measuring container.

-

Open the pressure gauge shut-off valve. The lever points in direction of flow.

-

Press the switch on the Hand held remote control (jumper) briefly to bleed the fuel system

-

Close the pressure gauge shut-off valve. The lever is perpendicular to the direction of flow - arrow -.

-

Press the switch on the Hand held remote control (jumper) until no more pressure increase is observed on the fuel pressure gauge.
-

Specification: approx. 6 bar positive pressure

If the specification was not obtained:

-

Check the delivery rate of the fuel pump.  See: Fuel Pump (FP) Delivery Quantity, Checking

Checking residual pressure

-

Check for leaks and residual pressure by observing the pressure loss on the pressure gauge.
-

After 10 minutes there must be a residual pressure of at least 3.75 bar.

The holding pressure drops below 3.75 bar:

-

Check the connection between the fuel pressure gauge and the fuel line for leaks.

-

Check the pressure gauge for leaks.

-

Check the fuel lines and their connections for leaks.

-

Replace the fuel filter with integrated fuel pressure regulator.

-

Replace the fuel pump.

Assembly is performed in the reverse order of removal. Note the following:

NOTE:  Before disconnecting the pressure gauge, release the fuel pressure by opening the shut-off valve. Hold a container under the connection.

Torque specifications

Fuel line to fuel rail : 22 Nm

Test Chart 1|Page 4232 > < Test Chart 1|Page 4230