Condenser HVAC: Service and Repair
Refrigerant Lines For Condenser, Removing and Installing

Refrigerant Lines For Condenser, Removing And Installing

Disconnecting

-

Discharge refrigerant circuit Refrigerant R134a - Servicing.

-

Remove noise insulation.

-

Remove entire front bumper.

-

Remove bolts - A - (tightening torque 20 Nm).

-

Remove refrigerant lines from condenser.

NOTE:  Seal open lines and connections at condenser with suitable caps (to prevent dirt and moisture).

Installing

Install in reverse order, paying attention to the following:

-

After attaching, check routing of refrigerant lines - A -. They must be inserted in brackets - B - provided and not make contact with other
components.

-

Replace O-rings - B - and - C -.

-

Check type of seal at connections and refrigerant lines (must be designed for same type of seal).

-

Evacuate and recharge refrigerant circuit. Refrigerant R134a - Servicing

Condenser Fan Motor Relay, HVAC > < Condenser, Removing and Installing