audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Housing Assembly HVAC > < Refrigerant Lines on Compressor, Removing and Installing|Page 11523
Page 1
background image

Hose/Line HVAC: Removal and Replacement
Refrigerant Lines on Evaporator Flange, Removing and Installing

Refrigerant Lines On Evaporator Flange, Removing And Installing

Disconnecting

-

Remove plenum chamber cover.

-

Discharge refrigerant circuit Refrigerant R134a - Servicing.

-

Remove nut - A - (tightening torque 25 Nm).

-

Remove refrigerant lines from evaporator and seal open connections.

NOTE:  Closing cap of replacement evaporator is a suitable means of sealing open connections at evaporator - D - and lines (to prevent dirt and
moisture).

Installing

Install in reverse order, paying attention to the following:

-

Replace O-rings - B - and - C -.

-

Install refrigerant lines such that they are not strained.

-

After installing refrigerant lines, check proper installation of grommet - E - and bushing - F -.

-

Check position of refrigerant lines to evaporator. They must not make contact with other components.

-

Check type of seal at connections and refrigerant lines (must be designed for same type of seal).

-

Evacuate and recharge refrigerant circuit. Refrigerant R134a - Servicing.

Housing Assembly HVAC > < Refrigerant Lines on Compressor, Removing and Installing|Page 11523