Discharge Air Temperature Sensor / Switch: Service and Repair
Right Footwell Vent Temperature Sensor G262, Removing and Installing

Right Footwell Vent Temperature Sensor G262, Removing And Installing

-

Remove operating and display module, Climatronic Control Module J255.

-

Reach through opening for operating and display module, Climatronic Control Module J255 and disconnect connector - A-.

-

Give Right Footwell Vent Temperature Sensor G262 -B - approx. 90 degrees  turn in direction of arrow.

-

Pull Right Footwell Vent Temperature Sensor G262 out of air conditioner.

NOTE:  observe arrangement of connectors to both sensors ( Left Footwell Vent Temperature Sensor G261 and Right Footwell Vent Temperature
Sensor G262 to avoid interchange).