Leak Detection Pump: Testing and Inspection
Leak Detection Pump (LDP) V144, Checking (Vehicles With FSI and TFSI-Engine

Leak Detection Pump (LDP) V144, Checking (vehicles with FSI and TFSI-engine)

Special tools, testers and auxiliary items required

-

Hand multimeter V.A.G 1526 A or V.A.G 1526 B

-

Voltage tester V.A.G 1527 B

-

Connector test kit V.A.G 1594 A or V.A.G 1594 C

-

Adapter cable V.A.G 1598/39

-

Test box V.A.G 1598/42

-

Vehicle Diagnostic, Testing and Information System VAS 5051 with diagnostic cable VAS 5051/5 A

Test conditions

-

Ignition switched on.