audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Customer Interest for Variable Induction Check Valve:|241022|Page 7201 > < Customer Interest for Variable Induction Check Valve:|241022
Page 2
background image

1. Use the vacuum pump to identify the vacuum leak in the system. Attach vacuum pump as shown in Figure 1.

2. Apply vacuum.

3. Identify leaking vacuum line by separating and blocking each section.

Tip: The vacuum line (06E 133 633) attached to the vacuum pump in Figure 1 is usually the causal part.

4. If a vacuum leak is identified, replace the appropriate vacuum line.

5. If vacuum stays stable during the test procedure, check corresponding actuator diaphragm.

^ DTC P2070 may be caused by a leak in the IMT Actuator diaphragm.

^ DTC P2006 and P2007 may be caused by a leak in the Manifold Runner Actuator diaphragm.

Warranty

Customer Interest for Variable Induction Check Valve:|241022|Page 7201 > < Customer Interest for Variable Induction Check Valve:|241022