A4 Quattro Wagon V6-3.2L (BKH) (2005)
Battery: Service and Repair
Quick-Charging
Quick-charging
CAUTION:
-
Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.
-
Always wear suitable protective clothing.
Danger of explosion.
-
Batteries produce explosive gasses while being charged.
-
Keep open flames and sparks away and DO NOT smoke near batteries.
-
The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.
-
Battery cell caps must NOT be removed while charging.
-
"Boosting" a sulfated battery a high charging rate can cause an explosion.
-
Ensure that battery is charged in a well ventilated area.
-
Precision tools must not be kept in the same room where batteries are being charged.
Tools may corrode due to chemical reaction.
CAUTION:
-
Battery must not be connected to vehicle electrical system when quick charging. Disconnect negative (-) and positive ( + ) battery terminals.
-
Never quick-charge a totally discharged battery. Effective charging will not take place.
NOTE:
-
The battery temperature must be at least 10 degrees C.
-
Quick-charging of batteries should only be performed in exceptional circumstances (e.g. boost starting) as rapid charging may cause damage.