Battery: Service and Repair
Quick-Charging

Quick-charging

CAUTION:

-

Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.

-

Always wear suitable protective clothing.
Danger of explosion.

-

Batteries produce explosive gasses while being charged.

-

Keep open flames and sparks away and DO NOT smoke near batteries.

-

The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.

-

Battery cell caps must NOT be removed while charging.

-

"Boosting" a sulfated battery a high charging rate can cause an explosion.

-

Ensure that battery is charged in a well ventilated area.

-

Precision tools must not be kept in the same room where batteries are being charged.
Tools may corrode due to chemical reaction.

CAUTION:

-

Battery must not be connected to vehicle electrical system when quick charging. Disconnect negative (-) and positive ( + ) battery terminals.

-

Never quick-charge a totally discharged battery. Effective charging will not take place.

NOTE:

-

The battery temperature must be at least 10 degrees C.

-

Quick-charging of batteries should only be performed in exceptional circumstances (e.g. boost starting) as rapid charging may cause damage.