A4 Quattro Wagon V6-3.2L (BKH) (2005)
Battery: Testing and Inspection
Electrolyte Specific Gravity - Batteries With Sealing Plugs, Checking
Electrolyte Specific Gravity - Batteries With Sealing Plugs, Checking
CAUTION:
-
Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.
-
Always wear suitable protective clothing.
-
When disposing of batteries, always pay attention to the appropriate regulations for batteries and sulfuric acid.
-
Proper battery sealing plugs must be used to ensure differing battery cover systems are sealed correctly. Use genuine sealing plugs of same
construction if lost or damaged.
-
The plugs must be installed with an O-ring seal.
Special tools, testers and auxiliary items required
-
Hydrometer (commercially available)
NOTE:
-
The electrolyte specific gravity test in conjunction with the battery test provides specific information on battery condition.
-
The temperature of the battery electrolyte must be at least 10 degrees C.
-
Electrolyte specific gravity can be checked immediately after charging battery.
Test sequence
-
Remove all battery plugs (battery cell sealing plugs).