Battery: Testing and Inspection
Electrolyte Specific Gravity - Batteries With Sealing Plugs, Checking

Electrolyte Specific Gravity - Batteries With Sealing Plugs, Checking

CAUTION:

-

Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.

-

Always wear suitable protective clothing.

-

When disposing of batteries, always pay attention to the appropriate regulations for batteries and sulfuric acid.

-

Proper battery sealing plugs must be used to ensure differing battery cover systems are sealed correctly. Use genuine sealing plugs of same
construction if lost or damaged.

-

The plugs must be installed with an O-ring seal.

Special tools, testers and auxiliary items required

-

Hydrometer (commercially available)

NOTE:

-

The electrolyte specific gravity test in conjunction with the battery test provides specific information on battery condition.

-

The temperature of the battery electrolyte must be at least 10 degrees C.

-

Electrolyte specific gravity can be checked immediately after charging battery.

Test sequence

-

Remove all battery plugs (battery cell sealing plugs).