audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Canister Purge Regulator Valve <--> [Canister Purge Control Valve]|Specifications|Page 7830 > < Canister Purge Regulator Valve <--> [Canister Purge Control Valve]|Specifications|Page 7828
Page 3
background image

-

Connect multimeter US 1119 (Fluke 83 or equivalent) and check resistance at across valve terminals.
Specified value: 22 - 30 Ohms

If resistance is NOT OK:

-

Replace EVAP canister purge regulator valve

Checking EVAP canister purge regulator valve voltage supply

Test conditions

-

Fuse for EVAP canister purge regulator valve OK.

-

Disconnect harness connector from EVAP canister purge regulator valve.

-

Connect VAG 1527B LED voltage tester between connector terminal 1 and engine Ground.

-

Operate starter motor. Specified value: LED must light up

If LED test light does not light:

-

Check wiring for open circuit between connector terminal 1 and fuse, according to wiring diagram. Repair if necessary.

If wiring is OK:

-

Check fuel pump relay. See: Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Relay/Testing and Inspection 

Checking signal to EVAP canister purge regulator valve

Canister Purge Regulator Valve <--> [Canister Purge Control Valve]|Specifications|Page 7830 > < Canister Purge Regulator Valve <--> [Canister Purge Control Valve]|Specifications|Page 7828