LDP Via Read Measuring Value Block (Mechanical Throttle)|Page 7850 > < LDP Via Read Measuring Value Block (Mechanical Throttle)|Page 7848
Page 3
background image

Display will appear as shown

Read measuring value block 
Enter display group number XXX

-

Press 0, 7 and 1 buttons to select "display group 71".

-

Press Q button to enter input.

Display will appear as shown

Read measuring value block

 ->

Reed closed

break 

Test OFF

NOTE:

-

Condition for continuing test is "Reed closed" on the display.

-

The display does not always show "Abort".

-

If the display. "reed open" appears: Briefly open the filler cap to reduce pressure - this will close the reed contact. Continue checking as follows:

-

Press 0 and 4 buttons to select Function 04: "Basic Setting". 

Display will appear as shown

System in basic adjustment 71

 ->

Reed closed

Test ON

-

The EVAP canister valve is opened to allow pressure relief in the system.

-

Then the LDP -V144 will be triggered.

-

The total procedure lasts approx. 60 seconds.

-

Press -> button

Display will appear as shown

System in Basic Adjustment 71

 ->

Reed open 

Syst.Test

Test ON

-

The system makes a test, the LDP -V144 starts running and shuts off when the pump running time reaches a pre-determined time-out.

-

The total procedure lasts approx. 60 seconds.

Display will appear as shown

System in Basic Adjustment 71

 ->

Reed open

Measurement

Test >ON

-

Measurement phase begins. The LDP -V144 is switched off and the ECM checks whether the reed contact has closed within 10 seconds.

If NO

Display will appear as shown

System in Basic Adjustment 71

 ->

Reed open

Messg.END

Syst. OK

-

The system is sealed and the measurement is ended.

-

Press -> button.

-

Press 0 and 6 buttons to select Function 06: "End output"

-

Press Q button to enter input.

If contact does not close within 10 seconds.

-

The LDP -V144 performs 4 pump strokes. The ECM compares the time it takes to carry out the pump strokes and the time until the reed contact
closes again.

Display will appear as shown