audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Electrolyte Level, Checking|Page 10610 > < Electrolyte Level, Checking|Page 10608
Page 1
background image

Battery: Testing and Inspection
No-Load Voltage, Checking

No-load Voltage, Checking

CAUTION!

-

Battery cell caps must be screwed in tightly when charging, measuring voltage or performing load tests.

-

Always comply with the following instructions otherwise a correct measurement cannot be assured.

Special tools, test equipment and auxiliary items

-

VAG1715 multimeter or

-

VAG1362 mini tester or

-

Multimeter (Fluke 83 or equivalent)

NOTE:

-

When testing the no-load voltage of a battery installed in a vehicle, make sure the battery Ground (GND) strap is disconnected.

-

The battery must not have been under a load for at least two hours before the test.

-

The battery must not have been charged at least two hours before the test.

Use the following procedure for testing the voltage of a battery which is not under load:

-

Switch ignition off.

-

Disconnect battery Ground strap.

-

 Measure voltage between battery terminals.
-

12.5 volts or higher: battery OK

-

Below 12.5 volts: recharge battery immediately

Electrolyte Level, Checking|Page 10610 > < Electrolyte Level, Checking|Page 10608