audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Level Sensor, Adaptation After Replacement|Page 13187 > < Fuel Level Sensor, Adaptation After Replacement
Page 2
background image

Rapid data transfer

HELP

Select function XX

-

Press buttons -1- and -0- to select function 10 and press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX

-

Press buttons -3- and -0- to insert channel 30.

-

Press -Q- button to confirm input.

Indicated on display

Channel 30 Adaptation 128

->

< -1 3- >

The display shows the adaptation value, for example 128.

NOTE:

-

128 is the adaptation value for the standard resistance range for the fuel gauge sender as set by the factory.

-

The resistance value for the fuel sender resistance range can be adjusted by ±8 ohms to give an adaptation value  between 120 and 136.

-

Press -> button.

Indicated on display

Channel 30 Adaptation 128
Input adaptation value XXXXX

-

Input adaptation value using keypad on VAG1551, fill in leading digits with zeroes "0"

Indicated on display

Channel 30 Adaptation 128

Q

Input adaptation value 00132

-

Press -Q- button to confirm input.

-

Indicated on display

Channel 30 adaptation 132

Q

< -1 3- >

-

Press -Q- button to confirm input.

-

Indicated on display

Channel 30 adaptation 132

Q

Store changed value?

-

Press -Q- button to confirm input.

-

Indicated on display

Channel 30 adaptation 132

->

Changed value is stored

-

Press -> button to end SRI adaptation.

Fuel Level Sensor, Adaptation After Replacement|Page 13187 > < Fuel Level Sensor, Adaptation After Replacement