A4 Sedan L4-1.8L Turbo (AWM) (2001)
Display Group 062
-
Observe display field 3 and 4.
-
Slowly depress accelerator pedal completely.
Percent indication in display field 3 must rise uniformly. The tolerance range 12 to 97% is not used completely during this.
Percent indication in display field 4 must also rise uniformly. In the process, the tolerance range of 4 to 49% is not completely utilized.
NOTE: The indicated value in display field 3 must always be about twice as large as the value in display field 4.
-
Press "08 - erase DTC memory" to end function <- button.
If indications do not resemble description:
-
Check voltage supply and wire connections of sensor for accelerator pedal position. See:
Checking voltage supply of Throttle Position (TP) sensor
-
Remove driver-side storage compartment.
-
Disconnect harness connector for accelerator pedal position sensor.
-
Switch ignition on.
-
Connect multimeter for voltage measurement as follows: