Leak Detection Pump: Testing and Inspection
LDP Via Read Measuring Value Block (Mechanical Throttle)
Leak Detection Pump (LDP) -V144, checking
Special tools needed:
-
VAG1526 A
-
VAG1527 B
-
VAG1594 A
-
VAG1598/22 (vehicles with mechanical accelerator cable)
-
VAG1598/31 (vehicles with electronic throttle control
-
VAS5051 with VAS5051/1
or
-
VAG1551 with VAG1551/3 A
Checking LDP via Read Measuring Value Block (vehicles with mechanical throttle control)
NOTE:
-
Always replace O-rings, sealing rings and gaskets.
-
Radiator fan must not come on during the test!
Troubleshooting requirements