Air Door Actuator / Motor: Service and Repair
Right Temperature Flap Motor V159, Removing and Installing

Right Temperature Flap Motor V159, Removing And Installing

NOTE:  This control motor moves two flaps, which are interlinked by way of a connecting rod installed in the air conditioner (not visible from outside).
In the event of problems with temperature control, the connection between the flaps can be checked with the air conditioner in position and the heater
core removed (for visual inspection, the flap can be viewed through the opening with the heater core removed). To check operation if applicable, reach
through slot for heater core into air conditioner and move the flaps via the external lever.

Removing

-

Remove glove compartment.

-

Disconnect connector - A -.

-

Remove bolts - B -.

-

Remove lever - C - of Right Temperature Flap Motor V159 from connecting rod - D -.

Installing

NOTE:  The control motor lever is color-coded. The lever for the Right Temperature Flap Motor V159 is dark purple

Reinstall all parts removed in reverse order, paying attention to the following:

-

Lay wiring harness such that it cannot come into contact with moving components (e.g. control motor lever).

-

Check and erase DTC memory; perform basic setting.

NOTE:  Operation of the control motor can be checked as follows: Connect the two contacts "5" and "6" in the control motor connector to a 12 V DC
source. The control motor moves as far as the stop in one direction. Interchanging positive and negative reverses direction. Use adapter for this purpose.