background image

Service Port HVAC: Description and Operation

Quick-release Coupling Connections In Refrigerant Circuit

-

Only valves and connections resistant to R134a refrigerant and the related refrigerant oils are to be used.

-

There are different connections (OD) for high and low pressure sides.

-

Discharge refrigerant circuit before removing valves or valve inserts.

-

Always screw on sealing caps.

Arrangement in vehicle Heating, air conditioning or Air conditioning

Connections with Schrader valve

A. Service connection (soldered in)
B. Schrader valve insert
C. O-ring (for valve)
D. Cap with seal

Connections with primary sealing valve

CAUTION:  Before unscrewing connection, connect service station and extract refrigerant. Refrigerant circuit must be empty to avoid possible injury.

Connection with high-pressure valve

1. Socket with external or internal thread
2. O-ring: 10.8 mm; 1.8 mm, identification: black or colored
3. Valve with groove for O-ring and external or internal thread M 8x1 for cap
4. O-ring for cap: 10.8 mm; 1.8 mm, identification: black or colored
5. Cap

Connection with low-pressure valve

Service Port HVAC|Description and Operation|Page 11900 > < How to Find Wiring Diagrams|Page 11896