Leak Detection Pump: Testing and Inspection
Leak Detection Pump (LDP) -V144-, Checking

Leak Detection Pump (LDP) V144, Checking

Special tools, testers and auxiliary items required

-

Multimeter V.A.G 1526 or equivalent.

-

Test Box 105 Pin VAG1598/42.

-

Adapter Lead Vag1598/39 VAG1598/39.

-

Adapter Lead Vag1598/39 VAG1598/39.

Test requirements

-

The Leak Detection Pump (LDP) V144 fuse OK. .

-

The ignition switched off.

Procedure

-

Remove the left rear wheel housing liner.

-

Disconnect the electrical harness connector - 3 - .

Checking internal resistance

-

Using the Multimeter V.A.G. 1526 A or equivalent, check them Leak Detection Pump (LDP) V144 for resistance as follows:

Leak Detection Pump (LDP) -V144- terminal

Specified value

- 1 - + - 3 -

640 to 720 Ohms

- 2 - + - 3 -

15 to 17 Ohms

If the specifications are not obtained:

-

Replace the Leak Detection Pump (LDP) -V144- .

If the specified values are obtained:

-

Check the voltage supply of the Leak Detection Pump (LDP) -V144- .

Checking voltage supply

NOTE:  The voltage for the Leak Detection Pump (LDP) -V144- is supplied via the Engine Control Module (ECM) J623.