Using the Multimeter V.A.G. 1526 A or equivalent, check the electrical harness connector for voltage.

Harness connector terminal

Measure to

- 3 -

Engine Ground (GND)

-

Operate the starter briefly.
Specified value: aprox. battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Using the Multimeter V.A.G. 1526 A or equivalent, check electrical harness connector terminal - 3 - via Fuel Metering Valve N290 to Engine
Control Module (ECM) J623 for open circuit.
Specified value: Wire resistance max 1.5 Ohms.

If the specification is not obtained:

-

Check the wiring for a short circuit to Battery positive (+) or an open circuit.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and if the voltage supply was OK:

Checking output wiring

-

Connect the test box 1598/42 to the wiring harness of the Engine Control Module (ECM) J623. The ECM is not connected.

-

Using the Multimeter V.A.G. 1526 A or equivalent, check the following wire connections for an open circuit.

Harness connector terminal

Test box Socket

- 1 - 

40