Switch off ignition.
If Leak Detection Pump (LDP) for fuel system is not activated (no operating noise audible):
-
Remove leak detection pump (LDP) V144 and disconnect the electrical connection.
Checking internal resistance
-
Connect hand multimeter V.A.G 1526 A or V.A.G 1526 B for resistance measurement as follows.
Leak detection pump (LDP) Terminal
Specified value
- 1 - + -3-
640 to 720 Ohms
- 2 - + -3-
15 to 17 Ohms
If specifications are not obtained:
-
Replace Leak Detection Pump (LDP) V144.
If specified values are achieved:
-
Check voltage supply of leak detection pump.
Checking voltage supply
NOTE: Voltage for leak detection pump is supplied via Motronic Engine Control Module (ECM) Power Supply Relay J271.
Test conditions
-
Fuse for leak detection pump OK
-
Connect voltage tester V.A.G 1527 B as follows:
Harness connector
Measure to
Terminal
- 3 -
Engine Ground (GND)
-
Briefly operate starter.
-
LED must light up.