Switch off ignition.

-

Connect test box V.A.G 1598/42 to wiring harness with adapter cable V.A.G 1598/39-1 or adapter cable V.A.G 1598/39-2. Clamp test box
Ground (GND) clip to battery negative terminal. The procedure will indicate whether the engine control module is to be connected to the test box
or not.

CAUTION:  To avoid damaging electronic components, switch to the corresponding measuring range and observe all test conditions before
connecting the test leads.

-

Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector Terminal

Test box V.A.G 1598/42Socket

- 2 -

4-Cyl. TFSI: B 8
6-Cyl. FSI: B 24

-

Repair wiring open circuit or short circuit according to wiring diagram.

If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:

-

Replace Leak Detection Pump (LDP) V144.

-

Observe procedures for after re-connecting engine control module (ECM).