A4 Sedan L4-2.0L Turbo (BPG) (2005)
Air Bypass Valve Solenoid: Testing and Inspection
Turbocharger Recirculating Valve N249, Checking
Special tools, testers and auxiliary items required
-
Multimeter V.A.G 1526 or equivalent.
-
Test Box 105 Pin VAG1598/42.
-
Adapter Lead Vag1598/39 VAG1598/39.
-
Adapter cable V.A.G 1598/39-1.
NOTE: Use only gold-plated terminals when servicing terminals in harness connector of Charge Air Pressure Sensor G31.
Test requirements
-
Fuses for the Engine Control Module (ECM) J623 OK.
-
Battery voltage at least 12.5 volts.
-
All electrical consumers such as, lights and rear window defroster, switched off.
-
On vehicles with automatic transmission, selector lever in position "P" or "N".
-
A/C switched off.
-
Ground (GND) connections between engine/transmission/chassis OK.
-
Ignition switched off.
Test sequence
-
Remove engine cover - arrows - .
-
Disconnect the electrical harness connector - 3 - from the Turbocharger Recirculating Valve N249.