Rotate Dial Gauge 0-30 mm VAS 6341/1 display to 0.

-

Check dial gauge for ease of movement.

-

Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A shows 350 ± 5 mbar.

-

Dial gauge must display between 4.1 mm and 4.33, otherwise, turn knurled nut until value is displayed.

-

Hand tighten lock nut.

-

Repeat measurement.

-

Reduce pressure to 0 mbar via Pressure Control Valve VAS 6342 .

-

Set Dial Gauge 0-30 mm VAS 6341/1 to 0.

NOTE:  The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.

-

Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A shows 350 ± 5 mbar.

-

Read value on dial indicator VAS 6341/1 and note.

-

Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A displays 650 mbar to 700 mbar.

-

Reduce pressure to 350 ± 5 mbar via Pressure Control Valve VAS 6342.

-

Read value on dial indicator VAS 6341/1 and note.

-

Add value 1 and 2 and divide by 2.

-

The result (mean value) must be 5 ± 0.25 mm.

-

If result (mean value) is not 5 ± 0.25 mm, correct adjustment, tighten lock nut hand-tight and repeat measurement.

-

If result (average) is 5 ± 0.25 mm, tighten lock nut and secure with sealing wax.

-

Secure securing plate - 1 - over vacuum diaphragm linkage.