Vacuum Check Valve HVAC: Testing and Inspection

Vacuum Supply and One-Way Valve, Testing

-

Detach hose -B- from two-way valve (N63) and connect vacuum gauge VAG1368 (or equivalent) to hose.

-

Start engine and run at idle until the readout has stabilized.

-

Switch off engine. Vacuum reading on gauge must not drop by more than 50 mbar within 2 minutes.

NOTES:

-

Specification for vacuum when engine running: greater than 250 mbar.

-

Removing and installing vacuum reservoir and one-way valve. See: Vacuum Reservoir HVAC/Service and Repair 

-

Testing -N63-, output Diagnostic Test Mode (DTM). See: Testing and Inspection/Scan Tool Testing and Procedures/Output Diagnostic Test Mode