audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking Oxygen Sensor Heating|Page 5690 > < Checking Oxygen Sensor Heating|Page 5688
Page 2
background image

If the specified value is not obtained:

-

Eliminate open or short circuit using wiring diagram.

If wiring OK:

-

Replace ECM.

Oxygen sensor heater, checking

NOTE:

-

Z29 = Oxygen Sensor (O2S) heater, bank 1

-

Z30 = Oxygen Sensor (O2S) heater, bank 2

-

For functional check of O2S heater -Z29- or -Z30-.

-

Disconnect heated oxygen sensor harness connector (component locations, refer to "Component Overview - II" See: Fuel Delivery and Air
Induction/Locations ).

-

Switch multimeter (Fluke 83 or equivalent) to 20 volt range and connect between terminals 1 (B+) and 2 (GND).

-

Start engine and let idle.
Specified value: approx. 12 to 14 V

If the specified value is not obtained:

-

Check oxygen sensor heater fuse.

-

Check fuel pump relay See: Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Relay/Testing and Inspection 

-

Check wiring for continuity between terminal 1 and fuse in fuse holder using wiring diagram, if necessary check terminal assignments.
Specified value: max. 1 ohms

-

Check wiring for continuity between terminals 2 and 8 on ECM connector E. 
Specified value: max. 1 ohms

-

Check wiring for continuity between terminals 2 and 3 of ECM connector E (O2S heater -Z30-).
Specified value: max. 1 ohms

Checking Oxygen Sensor Heating|Page 5690 > < Checking Oxygen Sensor Heating|Page 5688