audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Evaporative Emission Control Canister|Testing and Inspection|Page 6482 > < Evaporative Emission Control Canister|Testing and Inspection
Page 2
background image

-

Connect VAG 1598/19 test box to ECM.

-

Check following wiring connections for continuity.

Sensor -G172- connector

VAG 1598/19 test box

terminal number

 socket number

1

C2

3

CB

-

If necessary, eliminate open or short in wiring.

If wiring is OK and there is not at least 5 volts at the sensor harness connector:

-

Replace ECM.

-

Check wiring for continuity between harness connector and ECM.

Sensor -G112- connector

VAG 1598/19 test-box 

terminal number

socket number

2

B16

-

If necessary, eliminate open or short in wiring.

If wiring is OK:

-

Replace sensor for EVAP canister -G172-.