audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Vehicles Without ORVR|Page 6978 > < Vehicles Without ORVR
Page 2
background image

-

After installing, check continuity between metal ring on fuel filler neck and chassis Ground using multimeter, specified value: approx. 0
Ohms

7

-

Protector plate
-

For fuel filler neck

-

With Ground connection
-

Ensure Ground screw is tight before threading in mounting screw 

8

-

O-rings
-

Replace 

9

-

Bleed valve
-

Removing, installing, checking See Fig. 1.

Fig. 1 Bleed valve removing, installing, checking

-

To remove, unclip valve from side of filler neck.
-

Lever in rest position: Valve closed

-

Lever pressed in direction of arrow: Valve open

Vehicles Without ORVR|Page 6978 > < Vehicles Without ORVR