Effects of Signal Failure:
-

The system responds to failure to receive a signal from the oxygen sensor by cancelling the oxygen sensor control and suppressing the lambda
adaptation function.

-

The evaporative emissions control system reverts to emergency backup operation. The engine-management ECM operates according to a
stored emergency program.

OXYGEN SENSOR G130/G131:

Connector View - Oxygen Sensor G130/G131

Electrical Circuit - Oxygen Sensor G130/G131

-

Oxygen sensor G13O is the Post-Catalyst probe of Bank 1, G131 is that of Bank 2.

Effects of Signal Failure:
-

Closed oxygen sensor control is maintained in the event of failure in the post-converter oxygen sensor. However, failure in the post-converter
sensor makes it impossible to monitor operation of the catalytic converter. Catalyst function can not be checked if sensor malfunctions.

BENEFITS OF HEATED OXYGEN SENSORS: